Robust, one-sided, non-contact measurement of plastic wall thickness
The CHRocodile 2 K optical sensor uses infrared light to carry out highly precise, non-contact measurements of the wall thickness of non-transparent or opaque plastics.
Advantages
- Plastic wall thickness measured
The CHRocodile 2 K optical sensor uses infrared light for one-sided, non-contact measurement of plastic products, such as films, extruded blown films, preforms, PET bottles, blisters, and balloons – both inline and offline. - Precision results
The ultra-high dynamic response and outstanding signal-to-noise ratio ensure precise measuring results in a wide distance tolerance range. - Compact design
The sensor's compact design enables integration into tight spaces in production environments. - Exactly the right probe for your needs
Each one of our single point sensors consists of a controller, an optical fiber, and an optical probe. From our large selection of optical probes we can ensure a custom solution to suit your requirements. A list of our interferometric probes can be downloaded here.
Technical data
- Measurements/second: up to 4,000 Hz
- Interferometric measuring range: 15 µm - 1500 µm
- Resolution: 3 x 10-6 x upper measuring range limit
- Synchronization with external devices: trigger input, synchronization output, 5 encoder input